Ceiling HEPA Box Air Filter Module
Product Overview
Key Specifications
- Efficiency Class
- HEPA / ULPA
- Filtration Efficiency
- HEPA 99.97 / 99.99% @0.3μm; ULPA 99.999 / 99.9995 / 99.9999% @0.1–0.2μm
- Inlet Duct Size
- Ø 8" / 10" / 12" / 14" / 16"
- Box Type
- Fully disposable / room-side replaceable
Specifications
- Filter Media
- Glass fiber paper
- Frame
- Anodized aluminum frame
- Box Type
- Fully disposable / room-side replaceable
- Insulation
- 12 mm(t) internal + external, or external only
- Efficiency Class
- HEPA / ULPA
- Filtration Efficiency
- HEPA 99.97 / 99.99% @0.3μm; ULPA 99.999 / 99.9995 / 99.9999% @0.1–0.2μm
- Inlet Duct Size
- Ø 8" / 10" / 12" / 14" / 16"
Model Reference
| Model | Description | Size |
|---|---|---|
| HEPABOX-600-1210-130-12IN | Disposable ceiling HEPA box assembly filter 99.99% 600X1210X130mm 12-inch duct collar, external insulation 0.45m/s | 600 × 1210 × 130 mm |
| HEPABOX-570-1170-130-12IN | Disposable ceiling HEPA box assembly filter 99.99% 570X1170X130mm 12" + external insulation | 570 × 1170 × 130 mm |
| HEPABOX-600-600-130-12IN | Disposable ceiling HEPA box assembly filter 99.99% 600X600X130mm 12-inch duct collar | 600 × 600 × 130 mm |
| HEPABOX-570-570-130 | Disposable ceiling HEPA box assembly filter 99.99% 570X570X130mm 8" + external insulation | 570 × 570 × 130 mm |
| H-BOX-600-1210-170-10IN-NF | T-BAR room-side replaceable HEPA box assembly 99.99% 600X1210X170mm 10-inch duct collar, external insulation, aluminum frame, filter not included | 600 × 1210 × 170 mm |
| H-BOX-570-1170-170-10IN | Room-side replaceable HEPA box assembly filter 99.99% 570X1170X170mm aluminum frame, 10" duct collar + external insulation | 570 × 1170 × 170 mm |
| H-BOX-600-600-170-12IN | Room-side replaceable HEPA box assembly filter 99.99% 600X600X170mm 12" duct collar | 600 × 600 × 170 mm |
| H-BOX-570-570-170-12IN | Room-side replaceable HEPA box assembly filter 99.99% 570X570X170mm 12" duct collar | 570 × 570 × 170 mm |
Common sizes are listed above. Other sizes, frame materials and efficiency grades can be made to order — please quote the model or size when requesting a quotation.
Detailed Description
Disposable or replaceable: what is the difference?
The difference is how you change the filter once it is loaded. In the disposable type the filter and box are one piece and the whole unit is replaced; it is 130 mm deep. In the replaceable type the box stays in the ceiling and the 70 mm filter inside is removed from the room side; it is 170 mm deep.Disposable vs room-side replaceable (side section)
Box depth and how the filter is changed
Schematic, not to scale. Box depth excludes the collar and flexible duct above; an FFU with its own fan needs about 250 mm.
| Item | Fully disposable | Room-side replaceable |
|---|---|---|
| Box depth | 130 mm | 170 mm |
| When the filter is loaded | Replace the whole unit (box + filter) | Replace only the inner filter; the box stays |
| Inner filter size | Built into the box | 567×1177×70 mm / 567×567×70 mm |
| Access above the ceiling to change it? | Yes, disconnect the collar and flexible duct | No, done from the room side |
How much air does one unit supply?
| Frame size (mm) | Rated airflow | In m³/h | Filter face velocity |
|---|---|---|---|
| 600×1210, 570×1170 | 17.5 CMM | 1050 m³/h | 0.45 m/s |
| 600×600, 570×570 | 8.4 CMM | 504 m³/h | 0.45 m/s |
Original specification tables
Disposable type| Actual size (W x H x D) mm | Rated airflow (CMM) | Weight (KG) |
|---|---|---|
| 600x1210x130 | 17.5 | 21 |
| 570x1170x130 | 17.5 | 19 |
| 600x600x130 | 8.4 | 12 |
| 570x570x130 | 8.4 | 10 |
| Actual size (W x H x D) mm | Rated airflow (CMM) | Weight (KG) |
|---|---|---|
| 600x1210x170 | 17.5 | 19 |
| 570x1170x170 | 17.5 | 19 |
| 600x600x170 | 8.4 | 12.5 |
| 570x570x170 | 8.4 | 12.5 |
Where it is used
- Ceiling air supply in cleanrooms: optoelectronics, semiconductors, electronics - Operating rooms and healthcare spaces (for negative-pressure isolation rooms, see the hospital HEPA box) - Clean areas in food, pharmaceutical, biotech and packaging plantsFrequently Asked Questions
How much space is needed above the ceiling?
At minimum, room for the box itself: 130 mm for the disposable type and 170 mm for the replaceable type, plus space for the duct collar and the bend of the flexible duct — the actual height depends on how the ductwork runs on site. On an operating-room project we compared options: a fan filter unit (FFU) with its own fan needed 250 mm above the ceiling, so where the ceiling void is shallow a HEPA box fits more easily.
What filter goes into the replaceable type?
The 600×1210 and 570×1170 mm replaceable boxes take a 567×1177×70 mm inner filter; the 600×600 and 570×570 mm boxes take 567×567×70 mm. Both are 99.99% (@0.3 μm) glass-fiber HEPA. The box stays in the ceiling while the old filter is taken out from the room side and the new one put in; afterwards the 2 PAO test ports on the box can be used for a leak test.
How many units does a room need?
Number of units = supply airflow the room needs ÷ rated airflow per unit. Each unit is rated at 17.5 CMM (1050 m³/h, 600×1210 / 570×1170 mm) or 8.4 CMM (504 m³/h, 600×600 / 570×570 mm). How much supply air the room needs depends on its cleanliness class and air change rate, and is set by the HVAC design. A floor plan without dimensions or airflow is not enough to work it out — when asking for a quote, please give the room size and supply airflow, or the number of existing outlets and their opening size.
How do I choose between 8″, 10″, 12″ and 14″ duct collars?
It depends on the frame size and the ductwork on site; the aim is to keep the air from moving too fast in the collar. You can work it out: velocity in the collar = rated airflow ÷ collar cross-section. 17.5 CMM through a 12″ collar is about 4.0 m/s, through a 10″ collar about 5.8 m/s; 8.4 CMM through an 8″ collar is about 4.3 m/s. The smaller the collar, the higher the velocity, and the more noise and resistance. Where the ductwork is already in place, order the collar size that matches the existing flexible duct; the standard collar size of each model is listed in the model table.
Can you provide UL 900 or proof of original factory import?
UL 900 is a fire (flammability) performance standard for filters, not a filtration efficiency, so the two should be considered separately. Our standard product is a Taiwan-made aluminum-frame HEPA box. Some hospital specifications require the complete unit to be "imported in original factory condition, with factory and import certificates", or a stainless steel housing; the standard product does not meet that, and it needs a separate selection and quote — please send the specification with your inquiry.
Selection References
Before ordering, verify the efficiency grade, media type, and whether the operating environment fits your requirements.