NIPPON MUKI
H14L EN-Standard H14 HEPA Filter
Product Overview
H14L is an EN 1822 H14 compliant mini-pleats HEPA filter with 99.995% efficiency @ MPPS. Engineered for GMP-regulated pharmaceutical cleanrooms, biosafety cabinets and terminal filtration on process equipment. Scan-testable leak-free construction.
Key features
・EN 1822 H14 standard (@ MPPS)
・99.995% efficiency
・Mini-pleats construction, high airflow low PD
・Leak-free, scan-testable
Target industries:Pharmaceutical
Features & Specifications
| No. | Model | Efficiency | W (mm) | H (mm) | D (mm) | Airflow (CMM) | Airflow (CMH) | Initial PD (Pa) |
|---|---|---|---|---|---|---|---|---|
| 1 | H14L-Z-E25 | 99.995%@MPPS(H14) | 305 | 305 | 50 | 2.0 | 120 | 140 |
| 2 | H14L-10-E25 | 99.995%@MPPS(H14) | 610 | 610 | 50 | 10.0 | 598 | 140 |
| 3 | H14L-Z-E41 | 99.995%@MPPS(H14) | 305 | 305 | 65 | 3.0 | 180 | 170 |
| 4 | H14L-Z-E41 | 99.995%@MPPS(H14) | 305 | 610 | 65 | 8.0 | 480 | 170 |
| 5 | H14L-Z-E41 | 99.995%@MPPS(H14) | 457 | 457 | 65 | 8.0 | 480 | 170 |
| 6 | H14L-Z-E41 | 99.995%@MPPS(H14) | 610 | 610 | 65 | 15.0 | 900 | 170 |
| 7 | H14L-15-E41 | 99.995%@MPPS(H14) | 610 | 1220 | 65 | 18.5 | 1110 | 170 |
| 8 | H14L-Z-E41 | 99.995%@MPPS(H14) | 762 | 610 | 65 | 22.5 | 1350 | 170 |
| 9 | H14L-Z-E41 | 99.995%@MPPS(H14) | 915 | 610 | 65 | 25.0 | 1500 | 170 |
| 10 | H14L-Z-E41 | 99.995%@MPPS(H14) | 1220 | 610 | 65 | 30.5 | 1830 | 170 |
| 11 | H14L-Z-E23 | 99.995%@MPPS(H14) | 305 | 305 | 75 | 3.5 | 210 | 180 |
| 12 | H14L-Z-E23 | 99.995%@MPPS(H14) | 305 | 610 | 75 | 7.5 | 450 | 180 |
| 13 | H14L-Z-E23 | 99.995%@MPPS(H14) | 457 | 457 | 75 | 9.0 | 540 | 180 |
| 14 | H14L-17-E23 | 99.995%@MPPS(H14) | 610 | 610 | 75 | 17.0 | 1020 | 180 |
| 15 | H14L-Z-E23 | 99.995%@MPPS(H14) | 610 | 1220 | 75 | 21.0 | 1250 | 180 |
| 16 | H14L-Z-E23 | 99.995%@MPPS(H14) | 762 | 610 | 75 | 25.5 | 1530 | 180 |
| 17 | H14L-Z-E23 | 99.995%@MPPS(H14) | 1220 | 610 | 75 | 34.5 | 2070 | 180 |
| 18 | H14L-Z-E38 | 99.995%@MPPS(H14) | 305 | 305 | 98 | 5.0 | 300 | 220 |
| 19 | H14L-Z-E38 | 99.995%@MPPS(H14) | 305 | 610 | 98 | 11.0 | 660 | 220 |
| 20 | H14L-Z-E38 | 99.995%@MPPS(H14) | 457 | 457 | 98 | 12.5 | 750 | 220 |
| 21 | H14L-Z-E38 | 99.995%@MPPS(H14) | 610 | 610 | 98 | 24.0 | 1440 | 220 |
| 22 | H14L-Z-E38 | 99.995%@MPPS(H14) | 762 | 610 | 98 | 30.0 | 1800 | 220 |
| 23 | H14L-Z-E38 | 99.995%@MPPS(H14) | 1000 | 610 | 98 | 40.0 | 2400 | 220 |
Detailed Description
H14L is Nippon Muki’s EN-standard HEPA for GMP-regulated pharmaceutical environments. @ MPPS testing satisfies EU GMP Annex 1 requirements; scan testing verifies leak-free integrity.
Materials & Construction
| Property | Specification |
|---|---|
| Filter frame | ALUMINUM |
| Media | GLASS PAPER |
| Max. temperature | 60°C |
| Relative humidity | 95%RH |
| Separator | HOT MELT ADHESIVE |
| Gasket | SILICONE |
| Grille (downstream) | ALUMINUM |
| Grille (upstream) | ALUMINUM |
| Sealant | POLYURETHANE RESIN |
| Max airflow | Can be calculated on request |
| Max final PD (Pa) | 294 |
Airflow vs Pressure Drop (representative)
Applications
- Grade B terminal filters in pharmaceutical cleanrooms - Biosafety cabinets - Terminal filtration on aseptic process equipment - Vaccine / cell-therapy facilitiesSelection Notes
- For H13 (99.95%), consult Nippon Muki for options. - For non-heat applications, H14L is suitable; for heat resistance use H14CH/H14CU. - **50 mm / 75 mm / 98 mm** — greater depth = higher airflow, lower PD.Selection References
Before ordering, verify the efficiency grade, media type, and whether the operating environment fits your requirements.